SHOP NOW

Sterilization & Disinfectant Compatibility

Material Formalin Isopropyl Alcohol Ethyl Alcohol Ethylene Oxide Autoclave E-Beam 5 Megarads Gamma 5 Megarads Dry Heat 250F
Acetal Y Y Y Y Y N N N
ABS N N/A Y Y N Y Y N
Polypropylene Y Y Y Y N Y Y N
Polysulfone Y Y Y Y Y Y Y Y
Glass Filled Polypropylene Y Y Y Y N N N N
Chrome/Brass N Y Y Y Y Y Y Y
Buna-N/Nitrile Y Y Y N N Y Y Y
EPR/EPDM Y Y Y Y Y Y Y Y
Viton/FKM Y Y Y N N N N Y
Silicon Y Y Y Y Y Y Y Y
Kalrez Y Y Y Y Y N N Y

Key: Y = Excellent, recommended, N = Not recommended, N/A = Not applicable

Sterilization Methods

Disinfectants: Sterilized coupled or uncoupled at 70°F (20C)
Ethylene Oxide, EtO: Sterilized coupled of uncoupled, up to 5 repetitions, four hours max, 100% EtO at 110°F (43°C)
Autoclave: Sterilize uncoupled only, 30 min. max, 10 repetitions max, 250°F (121°C) max.
Electron Beam (E-Beam): Sterilize coupled or uncoupled, 50 kilograys max cumulative exposure.
GAMMA: Sterilized coupled or uncoupled, 50 kilograys max cumulative exposure.
Dry Heat: Sterilize uncoupled only, 250°F (121°C) 12 hours max.

Get In Touch

Contact LinkTech using the form provided.

Sign up for the monthly newsletter